Cor Vasa 2011, 53(3):138-140 | DOI: 10.33678/cor.2011.030

Has the technique of aortic valve replacement an effect on the postoperative fate of the patient?

Olga Ondrůšková*, David Nešpor, Jan Černý, Petr Němec
Centrum kardiovaskulární a transplantační chirurgie, Brno, Česká republika

Aim: The authors compare the outcomes of two techniques of aortic valve replacement in a Center of Cardiac and Transplant Surgery in the 2005-2009 period.

Patients and methods: In a group of 676 patients with hemodynamically significant aortic valve disease, 472 patients had surgery with continuous monofilament suture implantation while 204 patients had surgery using single polyfilament pledglets. The following parameters were assessed: time of ischemic cardiac arrest, implanted valve size, postoperative complications (in particular early and late leak).

Results: Comparison of the outcomes of both groups revealed a significant difference only in the time of ischemic cardiac arrest, with no difference between the groups in the other monitored parameters.

Conclusion: Both techniques of aortic valve replacement are comparable if properly indicated and performed flawlessly in technical terms.

Keywords: Aortic valve replacement; Technique of implantation; Coronary heart ischeming cardiac arrest; Paravalvular leak

Published: March 1, 2011  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Ondrůšková O, Nešpor D, Černý J, Němec P. Has the technique of aortic valve replacement an effect on the postoperative fate of the patient? Cor Vasa. 2011;53(3):138-140. doi: 10.33678/cor.2011.030.
Download citation

References

  1. Dominik J. Kardiochirurgie. Praha: Grada, 1998:73.
  2. Cooley DA. Simplified techniques of valve replacement. J Card Surg 1992;7:357-362. Go to original source... Go to PubMed...
  3. Cleland J. A universally applicable continuous suture technique for insertion of aortic valve prostheses. Ann Thorac Surg 1975;19:719-724. Go to original source... Go to PubMed...
  4. Qicai H, Zili C, Zhengfu H, et al. Continuous-suture technique in aortic valve replacement. J Card Surg 2006;21:178-181. Go to original source... Go to PubMed...
  5. Laks H, Pearl JM, Barthel SW, et al. Aortic valve replacement using a continuous suture technique. J Card Surg 1993;8:459-465. Go to original source... Go to PubMed...
  6. Qicai H, Zili C, Zhengfu H, et al. Continuous-suture technique in aortic valve replacement. J Card Surg 2006;21:178-181. Go to original source... Go to PubMed...
  7. Hjelms E, Velhelmsen R, Rygg IH. Continuous suture technique in prosthetic aortic valve replacement. J Card Surg (Torino) 1982;23:145-148.
  8. LaPar DJ, Ailawadi G, Bhamidipati CM, et al. Use of a nonpledgeted suture technique is safe and efficient for aortic valve replacement. J Thorac Cardiovasc Surg 2011;141:388-393. Go to original source... Go to PubMed...
  9. Englberger L, Schaff HV, Jamieson WR. Importance of implant technique on risk of major paravalvular leak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT). Eur J Cardiothorac Surg 2005;28:838-843. Go to original source... Go to PubMed...
  10. Nair SK, Bhatnagar G, Valencia O, Chandrasekaran V. Effect of valve suture technique on incidence of paraprosthetic regurgitation and 10-year survival. Ann Thorac Surg 2010;89:1171-1179. Go to original source... Go to PubMed...




Cor et Vasa

You are accessing a site intended for medical professionals, not the lay public. The site may also contain information that is intended only for persons authorized to prescribe and dispense medicinal products for human use.

I therefore confirm that I am a healthcare professional under Act 40/1995 Coll. as amended by later regulations and that I have read the definition of a healthcare professional.