Cor Vasa 2012, 54(11-12):e393-e400 | DOI: 10.1016/j.crvasa.2012.11.005
The influence of the technology on the success of the treatment of paroxysmal atrial fibrillation - Single center experience
- a Kardiocentrum, Nemocnice České Budějovice, a. s., České Budějovice, Česká republika
- b I. interní klinika - kardiologická, Lékařská fakulta Univerzity Palackého a Fakultní nemocnice Olomouc, Olomouc, Česká republika
- c Zdravotně sociální fakulta, Jihočeská univerzita v Českých Budějovicích, Česká republika
Introduction: Pulmonary vein isolation (PVI) is considered to be a cornerstone of invasive therapy of paroxysmal atrial fibrillation (PAF). However, numerous technologies appeared on the market during last 10 years and besides typical "point-by-point" ablation, other "single-burn" technologies or remote navigation emerged.
Goal: The aim of this article is to summarize single center experience with PVI using different technologies.
Methods and results: The study was conducted in partially retrospective and mainly prospective manner. Consecutive cohorts of patients with PAF were followed after their index procedure using four different systems (CARTO XP, pulmonary vein ablation catheter [PVAC], CARTO3 and Sensei robotic system). After 3-month blanking period, repeated 7-day Holters were carried out every three months following the index procedure, which consisted of catheter-based radiofrequency PVI. Documented episodes of AF lasting > 60 s on any of these 7-day Holters were considered a failure of treatment. Using of the PVAC technology was associated with the shortest procedure duration when compared to any other system (p < 0.0001 for all) and significant shortening of fluoroscopic time when compared to CARTO XP (p < 0.0001). Using of novel CARTO3 mapping system or robotic navigation led to significant decrease of procedural time when compared to older 3D mapping system CARTO XP (p < 0.0001). Arrhythmia free survival at 12 months following the index procedure was 65.8%, 68.7%, 75% and 76.1% when using CARTO XP, PVAC, CARTO3 and robotic navigation, respectively. Using of either CARTO3 or robotic navigation system led to significant improvement of AF-free survival (log-rank p < 0.01). One major vascular complication was recorded in the robotic group of patients while none in other groups. No minor or major late complications (beyond 30 days following the index procedure) were noted in any of the groups.
Conclusions: Novel technologies bring significantly better results in terms of arrhythmia recurrence and allow for shorter procedure duration and lower radiation burden both for patients and the operating physicians.
Keywords: Comparison of technologies; Duty-cycled radiofrequency energy; Paroxysmal atrial fibrillation; Pulmonary vein ablation catheter; Robotic technology; 3D mapping systems
Received: October 23, 2012; Accepted: November 9, 2012; Published: November 1, 2012 Show citation
References
- A.J. Camm, G.Y.H. Lip, R. De Caterina, et al., 2012 focused update of the ESC Guidelines for the management of atrial fibrillation. An update of the 2010 ESC Guidelines for the management of atrial fibrillation. Developed with the special contribution of the European Heart Rhythm Association, Europace 14 (2012) 1385-1413.
Go to original source...
Go to PubMed...
- H. Calkins, K.H. Kuck, R. Cappato, et al., 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design, Europace 14 (2012) 528-606.
Go to original source...
Go to PubMed...
- C. Steinwender, S. Honig, F. Leisch, et al., Acute results of pulmonary vein isolation in patients with paroxysmal atrial fibrillation using a single mesh catheter, Journal of Cardiovascular Electrophysiology 20 (2009) 147-152.
Go to original source...
Go to PubMed...
- S.R. Dukkipati, P. Neuzil, J. Kautzner, et al., The durability of pulmonary vein isolation using the visually guided laser balloon catheter: multicenter results of pulmonary vein remapping studies, Heart Rhythm 9 (2012) 919-925.
Go to original source...
Go to PubMed...
- L.V. Boersma, M.C. Wijffels, H. Oral, et al., Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter, Heart Rhythm 5 (2008) 1635-1642.
Go to original source...
Go to PubMed...
- M. Kühne, S. Knecht, D. Altmann, et al., Validation of a novel spiral mapping catheter for real-time recordings from the pulmonary veins during cryoballoon ablation of atrial fibrillation, Heart Rhythm 2012, doi: 10.1016/j.hrthm.2012.10.009. [Epub ahead of print]
Go to original source...
Go to PubMed...
- M. Martinek, C. Lemes, E. Sigmund, et al., Clinical impact of a new open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation, Pacing and Clinical Electrophysiology 35 (2012) 1312-1318.
Go to original source...
Go to PubMed...
- E.P. Gerstenfeld, New technologies for catheter ablation of atrial fibrillation, Current Treatment Options in Cardiovascular Medicine 13 (2011) 393-401.
Go to original source...
Go to PubMed...
- A. Bulava, J. Haniš, D. Sitek, et al., Catheter ablation for paroxysmal atrial fibrillation: a randomized comparison between multielectrode catheter and point-by-point ablation, Pacing and Clinical Electrophysiology 33 (2010) 1039-1046.
Go to original source...
Go to PubMed...
- S. Fredersdorf, S. Weber, C. Jilek, et al., Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator, Journal of Cardiovascular Electrophysiology 20 (2009) 1097-1101.
Go to original source...
Go to PubMed...
- M. Wieczorek, R. Hoeltgen, M. Brueck, et al., Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results, Journal of Interventional Cardiac Electrophysiology 27 (2010) 23-31.
Go to original source...
Go to PubMed...
- G. Stabile, M. Scaglione, M. del Greco, et al., Reduced fluoroscopy exposure during ablation of atrial fibrillation using a novel electroanatomical navigation system: a multicentre experience, Europace 14 (2012) 60-65.
Go to original source...
Go to PubMed...
- A. Bulava, J. Haniš, D. Sitek, et al., Randomized comparison of pulmonary vein isolation using robotic and manual approach - interim results and procedural characteristics of the ROMA study, Europace 14 (Suppl 1) (2012) i86.
- Y. Van Belle, P. Janse, M.J. Rivero-Ayerza, et al., Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome, European Heart Journal 28 (2007) 2231-2237.
Go to original source...
Go to PubMed...
- J.G. Andrade, P. Khairy, P.G. Guerra, et al., Efficacy and safety of cryoballoon ablation for atrial fibrillation: a systematic review of published studies, Heart Rhythm 8 (2011) 1444-1451.
Go to original source...
Go to PubMed...
- L. Koch, K.G. Haeusler, J. Herm, et al., Mesh ablator vs. cryoballoon pulmonary vein ablation of symptomatic paroxysmal atrial fibrillation: results of the MACPAF study, Europace 14 (2012) 1441-1449.
Go to original source...
Go to PubMed...
- F. Gaita, J.F. Leclercq, B. Schumacher, et al., Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon, Journal of Cardiovascular Electrophysiology 22 (2011) 961-968.
Go to original source...
Go to PubMed...
- S.C. Herrera, T. Deneke, M. Hocini, et al., Incidence of asymptomatic intracranial embolic events after pulmonary vein isolation: comparison of different atrial fibrillation ablation technologies in a multicenter study, Journal of the American College of Cardiology 58 (2011) 681-688.
Go to original source...
Go to PubMed...
- L.D. Sauren, Y. Van Belle, L. De Roy, et al., Transcranial measurement of cerebral microembolic signals during endocardial pulmonary vein isolation: comparison of three different ablation techniques. Journal of Cardiovascular Electrophysiology 20 (2009) 1102-1107.
Go to original source...
Go to PubMed...
- D.S. Lee, P. Dorian, E. Downar, et al., Thrombogenicity of radiofrequency ablation procedures: what factors influence thrombin generation?, Europace 3 (2001) 195-200.
Go to original source...
Go to PubMed...
- M. Bendszus, G. Stoll, Silent cerebral ischaemia: hidden fingerprints of invasive medical procedures, Lancet Neurology 5 (2006) 364-372.
Go to original source...
Go to PubMed...
- R.W. Kruis, F.A. Vlasveld, D. Van Dijk, The (un)importance of cerebral microemboli, Seminars in Cardiothoracic and Vascular Anesthesia 14 (2010) 111-118.
Go to original source...
Go to PubMed...