Cor Vasa 2012, 54(5-6):e167-e175 | DOI: 10.1016/j.crvasa.2012.05.007

Optical coherence tomography in interventional cardiology - research field or future daily routine?

Jan Kaňovskýa, Otakar Bočeka, Pavel Červinkab, Tomáš Ondrúša, Petr Kalaa
a Interní kardiologická klinika, Lékařská fakulta Masarykovy univerzity a Fakultní nemocnice Brno, Brno, Česká republika
b Klinika kardiologie, Masarykova nemocnice, Ústí nad Labem, Česká republika

Keywords: Acute coronary syndrome; Coronary morphology; Optical coherent tomography

Received: April 29, 2012; Revised: May 22, 2012; Accepted: May 23, 2012; Published: May 1, 2012  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Kaňovský J, Boček O, Červinka P, Ondrúš T, Kala P. Optical coherence tomography in interventional cardiology - research field or future daily routine? Cor Vasa. 2012;54(5-6):e167-175. doi: 10.1016/j.crvasa.2012.05.007.
Download citation

References

  1. Sigwart U, Puel J, Mirkovitch V, Joffre F, Kappenberger L. Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. N Engl J Med 1987;316: 701-6. Go to original source... Go to PubMed...
  2. Suter MJ, Nadkarni SK, Weisz G, et al. Intravascular optical imaging technology for investigating the coronary artery. JACC Cardiovasc Imaging 2011;4:1022-39. Go to original source... Go to PubMed...
  3. Bom N, Lancée CT, Van Egmond FC. An ultrasonic intracardiac scanner. Ultrasonics 1972;10:72-6. Go to original source... Go to PubMed...
  4. Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science 1991;254:1178-81. Go to original source...
  5. Kume T, Akasaka T, Kawamoto T, et al. Assessment of coronary intima-media thickness by optical coherence tomography: comparison with intravascular ultrasound. Circ J 2005;69:903-7. Go to original source... Go to PubMed...
  6. Chinn SR, Swanson EA, Fujimoto JG. Optical coherence tomography using a frequency-tunable optical source. Opt Lett 1997;22:340-2. Go to original source... Go to PubMed...
  7. Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon DI. Intracoronary optical coherence tomography: a comprehensive review clinical and research applications. JACC Cardiovasc Interv 2009;2:1035-46. Go to original source... Go to PubMed...
  8. Suzuki N, Guagliumi G, Bezerra HG, et al. The impact of an eccentric intravascular ImageWire during coronary optical coherence tomography imaging. EuroIntervention 2011;6:963-9. Go to original source... Go to PubMed...
  9. Prati F, Regar E, Mintz GS, et al. Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 2010;31:401-15. Go to original source... Go to PubMed...
  10. Tahara S, Chamié D, Baibars M, Alraies C, Costa M. Optical coherence tomography endpoints in stent clinical investigations: strut coverage. Int J Cardiovasc Imaging 2011;27:271-87. Go to original source... Go to PubMed...
  11. Guagliumi G, Musumeci G, Sirbu V, et al. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents. JACC Cardiovasc Interv 2010;3:531-9. Go to original source... Go to PubMed...
  12. Guagliumi G, Costa MA, Sirbu V, et al. Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: optical coherence tomography substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial. Circulation 2011;123:274-81. Go to original source... Go to PubMed...
  13. Guagliumi G, Sirbu V, Bezerra H, et al. Strut coverage and vessel wall response to zotarolimus-eluting and bare-metal stents implanted in patients with ST-segment elevation myocardial infarction: the OCTAMI (Optical Coherence Tomography in Acute Myocardial Infarction) Study. JACC Cardiovasc Interv 2010;3:680-7. Go to original source... Go to PubMed...
  14. Guagliumi G, Sirbu V, Musumeci G, et al. Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI). Circ Cardiovasc Interv 2010;3:367-75. Go to original source... Go to PubMed...
  15. Barlis P, Regar E, Serruys PW, et al. An optical coherence tomography study of a biodegradable vs. durable polymer-coated limus-eluting stent: a LEADERS trial sub-study. Eur Heart J 2010;31:165-76. Go to original source... Go to PubMed...
  16. Adriaenssens T, Dens J, Ughi G, et al. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study. EuroIntervention 2011;7 Suppl K:K100-5. Go to original source... Go to PubMed...
  17. Poerner TC, Otto S, Gassdorf J, et al. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods. EuroIntervention 2011;7 Suppl K:K93-99. Go to original source... Go to PubMed...
  18. www.clinicaltrials.gov
  19. Kume T, Akasaka T, Kawamoto T, et al. Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 2006;97:1713-7. Go to original source... Go to PubMed...
  20. Kume T, Akasaka T, Kawamoto T, et al. Assessment of coronary arterial plaque by optical coherence tomography. Am J Cardiol 2006;97:1172-5. Go to original source... Go to PubMed...
  21. Miyamoto Y, Okura H, Kume T, et al. Plaque characteristics of thin-cap fibroatheroma evaluated by OCT and IVUS. JACC Cardiovasc Imaging 2011;4:638-46. Go to original source... Go to PubMed...
  22. Yabushita H, Bouma BE, Houser SL, et al. Characterization of human atherosclerosis by optical coherence tomography. Circulation 2002;106:1640-5. Go to original source...
  23. Kubo T, Xu C, Wang Z, Van Ditzhuijzen NS, Bezerra HG. Plaque and thrombus evaluation by optical coherence tomography. Int J Cardiovasc Imaging 2011;27:289-98. Go to original source... Go to PubMed...
  24. Radu M, JŅrgensen E, Kelbaek H, Helqvist S, Skovgaard L, Saunamäki K. Optical coherence tomography at follow-up after percutaneous coronary intervention: relationship between procedural dissections, stent strut malapposition and stent healing. EuroIntervention 2011;7:353-61. Go to original source... Go to PubMed...
  25. Kume T, Okura H, Miyamoto Y, et al. Natural history of stent edge dissection, tissue protrusion and incomplete stent apposition detectable only on optical coherence tomography after stent implantation. Circ J 2012;76: 698-703. Go to original source... Go to PubMed...
  26. Mehanna EA, Attizzani GF, Kyono H, Hake M, Bezerra HG. Assessment of coronary stent by optical coherence tomography, methodology and definitions. Int J Cardiovasc Imaging 2011;27:259-69. Go to original source... Go to PubMed...
  27. Barlis P, Sianos G, Ferrante G, Del Furia F, D'Souza S, Di Mario C. The use of intra-coronary optical coherence tomography for the assessment of sirolimus-eluting stent fracture. Int J Cardiol 2009;136:e16-20. Go to original source... Go to PubMed...
  28. Ino Y, Kubo T, Tanaka A, et al. Difference of culprit lesion morphologies between ST-segment elevation myocardial infarction and non-ST-segment elevation acute coronary syndrome: an optical coherence tomography study. JACC Cardiovasc Interv 2011;4:76-82. Go to original source... Go to PubMed...
  29. Imola F, Mallus MT, Ramazzotti V, et al. Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention. EuroIntervention 2010;6:575-81. Go to original source... Go to PubMed...
  30. Stefano GT, Bezerra HG, Attizzani G, et al. Utilization of frequency domain optical coherence tomography and fractional flow reserve to assess intermediate coronary artery stenoses: conciliating anatomic and physiologic information. Int J Cardiovasc Imaging 2011;27:299-308. Go to original source... Go to PubMed...
  31. Yoshimura S, Kawasaki M, Yamada K, et al. OCT of human carotid arterial plaques. JACC Cardiovasc Imaging 2011;4:432-6. Go to original source... Go to PubMed...
  32. Reimers B, Nikas D, Stabile E, et al. Preliminary experience with optical coherence tomography imaging to evaluate carotid artery stents: safety, feasibility and techniques. EuroIntervention 2011;7:98-105. Go to original source... Go to PubMed...
  33. Jones MR, Attizzani GF, Given CA 2nd, Brooks WH, Costa MA, Bezerra HG. Intravascular Frequency-Domain Optical Coherence Tomography Assessment of Atherosclerosis and Stent-Vessel Interactions in Human Carotid Arteries. AJNR Am J Neuroradiol 2012;doi: 10.3174/ajnr.A3016 [Epub ahead of print]. Go to original source... Go to PubMed...
  34. Yonetsu T, Kakuta T, Lee T, et al. Assessment of acute injuries and chronic intimal thickening of the radial artery after transradial coronary intervention by optical coherence tomography. Eur Heart J 2010;31:1608-15. Go to original source... Go to PubMed...
  35. Stefano GT, Mehanna E, Parikh SA. Imaging a spiral dissection of the superficial femoral artery in high resolution with optical coherence tomography - Seeing is believing. Catheter Cardiovasc Interv 2012;doi: 10.1002/ccd.24292. [Epub ahead of print]. Go to original source... Go to PubMed...
  36. Tatebe S, Fukumoto Y, Sugimura K, et al. Optical coherence tomography as a novel diagnostic tool for distal type chronic thromboembolic pulmonary hypertension. Circ J 2010;74:1742-4. Go to original source... Go to PubMed...
  37. Okamura T, Onuma Y, Garcia-Garcia HM, et al. First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography. EuroIntervention 2011;6:1037-45. Go to original source... Go to PubMed...
  38. Guagliumi G, Sirbu V. Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 2008;72:237-247. Go to original source... Go to PubMed...
  39. Farooq V, Okamura T, Gogas BD, et al. 3D reconstructions of optical frequency domain imaging to improve understanding of conventional PCI. JACC Cardiovasc Imaging 2011;4:1044-6. Go to original source... Go to PubMed...
  40. Tu S, Xu L, Ligthart J, et al. In vivo comparison of arterial lumen dimensions assessed by co-registered three-dimensional (3D) quantitative coronary angiography, intravascular ultrasound and optical coherence tomography. Int J Cardiovasc Imaging 2012;doi: 10.1007/s10554-012-0016-6 [Epub ahead of print]. Go to original source... Go to PubMed...
  41. Liu L, Gardecki JA, Nadkarni SK, et al. Imaging the subcellular structure of human coronary atherosclerosis using micro-optical coherence tomography. Nat Med 2011; 17:1010-4. Go to original source... Go to PubMed...




Cor et Vasa

You are accessing a site intended for medical professionals, not the lay public. The site may also contain information that is intended only for persons authorized to prescribe and dispense medicinal products for human use.

I therefore confirm that I am a healthcare professional under Act 40/1995 Coll. as amended by later regulations and that I have read the definition of a healthcare professional.