Cor Vasa 2010, 52(Suppl.):44-47 | DOI: 10.33678/cor.2010.204
Infections of cardiac implantable electronic devices and their prevention
- III. interní-kardiologická klinika, Kardiocentrum, Fakultní nemocnice Královské Vinohrady a 3. lékařská fakulta Univerzity Karlovy, Praha, Česká republika
The last quarter of the past century has seen exponential growth in implantable electronic device use. The rate of infection after implantation of these devices is low, but clinically important. Appropriate diagnostic and therapeutic procedures are necessary for proper management of these complications.
Keywords: Cardiac implantable electronic devices; Infection; Lead; Extraction
Published: December 1, 2010 Show citation
References
- Klug D, Balde M, Pavin D, et al. Risk factors related to infections of implanted pacemaker and cardioverter-defibrillators: results of a large prospective study. Circulation 2007;116:1349-1355.
Go to original source...
Go to PubMed...
- Bakker PF, Hauer RN, Wever EF. Infections involving implanted cardioverter defibrillator devices. PACE 1992;15:654-658.
Go to original source...
Go to PubMed...
- Fu EY, Shepard RK. Permanent pacemaker infections. Cardiac Electrophysiol Rev 1999;3:39-41.
Go to original source...
- Harcombe AA, Newell SA, Luxman PF, et al. Late complications following permanent pacemaker implantation or elective unit replacement. Heart 1998;24:247-254.
Go to original source...
Go to PubMed...
- Chua JD, Wilkoff BL, Lee I, et al. Diagnosis and managment of infections involving implantable electrophysiologic cardiac devices. Ann Intern Med 2000;133:604-608.
Go to original source...
Go to PubMed...
- Bytešník J. 25 let od první implantace kardioverteru-defibrilátoru v Československu a další vývoj této léčby v České republice. Interv Akut Kardiol 2009;8:224-228.
- Da Costa A, Kirkorian G, Cuherat M, et al. Antibiotic prophylaxis for permanent pacemaker implantation: A meta-analysis. Circulation 1998;97: 1796-1801.
Go to original source...
Go to PubMed...
- Klug D, Wallet F, Lacroix D, et al. Local symptoms at the site of pacemaker implantation indicate latent systemic infection. Heart 2004;90:882-886.
Go to original source...
Go to PubMed...
- Izquierdo R, Llorente C, Mayio J, et al. Pacemaker infection due to Aspergillus: report of two cases and literature review. Clin Cardiol 2006;28:36-38.
Go to original source...
Go to PubMed...
- Spinler SA, Nawarskas JJ, Foote EF, et al. Clinical presentation and analysis of risk factors for infectious complications of implantable cardioverter-defibrillator implantations at a University Medical Center. Clinical Infectious Diseases 1998;26:1111-1116.
Go to original source...
Go to PubMed...
- Kiviniemi MS, Pirnes MA, Eranen HJ, et al. Complications related to permanent pacemaker therapy. Paging Clin Electrophysiol 1999;22:711-720.
Go to original source...
Go to PubMed...
- Chauahan A, Grace AA, Newel SA. Early complications after dual chamber versus single chamber pacemaker implantation. Pacing Clin Electrophysiol 1994;17:2012-2015.
Go to original source...
Go to PubMed...
- Burri H, Sunthorn H, Shah D, Abdollah H. Complications of pacemaker leads. Heart 2003;89:1421.
Go to original source...
Go to PubMed...
- Aggarwal RK, Connelly DT, Ray SG, Charles RG. Early complications of permanent pacemaker implantation: no diference between dual and single chamber systems. Br Heart J 1995;73:571-575.
Go to original source...
Go to PubMed...
- Pakarinen S, Oikarinen L, Toivonen L. Short-term implantation - related complications of cardiac rhythm management device therapy: a retrospective single-centre 1-year survey. Europace 2010;12:15-16.
Go to original source...
Go to PubMed...
- Ellenbogen KA, Wood MA, Shepard RK. Delay complications following permanent pacemaker implantation. Pacing Clin Electrophysiol 2002;25:1155-1158.
Go to original source...
Go to PubMed...
- Klug D, Balde M, Pavin D, et al.; for the PEOPLE Study Group. Risk factors related to infections of implantable pacemakers and cardioverter-defibrillators: results of a large prospective study. Circulation 2007;116:1349-1355.
Go to original source...
Go to PubMed...
- Da Costa A, Levievre H, Kirkorian G, et al. Role of the preaxillary flora in pacemaker infections. Circulation 1998;97:1791-1795.
Go to original source...
Go to PubMed...
- Margey R, McCann H, Blake G, et al. Contemporary management of and outcomes from cardiac device related infections. Europace 2010;12:64-70.
Go to original source...
Go to PubMed...
- Novák M, Dvořák P, Kamarýt P, et al. Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes. Europace 2009;11:1510-1516.
Go to original source...
Go to PubMed...
- Singer I, Hutschin GM, Mirowski M, et al. Pathologic findings related to the lead system and repeat defibrillations in patients with the automatic implantable cardioverter defibrillator. J Am Coll Cardiol 1987;10:382-388.
Go to original source...
Go to PubMed...
- Scott PA, Chow W, Ellis E, et al. Extraction of pacemaker and implantable cardioverter defibrillator leads: a single-centre study of electrosurgical and laser extraction. Europace 2009;11:1501-1504.
Go to original source...
Go to PubMed...
- Schulze CM, Grammes JA, Saari CS, et al. Percutaneous extraction of infected leads in patients with intracardiac vegetations and implications for reimplantation of infected leads with intracardiac vegetations for reimplantation: A single center experience. Heart Rhythm Society Scientific Sessions, New Orleans, LA, Abstract P3-84.
- Calvagna GM, Evola R, Scardace G, Valsecchi S. Single-operator experience with a mechanical approach for removal of pacing and implantable defibrillator leads. Europace 2009;11:1505-1509.
Go to original source...
Go to PubMed...
- Kennergren C. Cardiac implantable electronic device treatment: taking care of complications. Europace 2009;11:1419-1420.
Go to original source...
Go to PubMed...